6.20 OpENING ThE DOOR

To clean the glass and carry out stove maintenance, open the door by pulling the handle.
a
While the stove is operating the door must remain closed and may only be opened for maintenance interventions when the appliance
is off and cold.

6.21 STOvE hUmIDIfIER

The stove comes equipped as standard with a humidifier positioned
below the upper cover of the stove (see Figure).
The humidifier holds 230 ml of water which will last between two and
three days depending on the stove's use.
If it is necessary to clean the humidifier tank, it can be accessed with
the stove off and disconnected from the power supply, simply by lifting
the upper closure element being careful not to damage the painted
parts of the stove.
a
When refilling the humidifier do not exceed the maximum
capacity, shown as MAX, since this could lead to damage to
the appliance.

6.22 DISpOSAL Of ASh

Ash from natural (non-treated) wood burned in stoves or open fireplaces is composed mainly of calcium, silicon, potassium and magnesium. The
ashes can therefore be used as a fertiliser for plants or in the garden, albeit not exceeding 2.6 kg per 10 m².
a
The ashes should be placed in a metal container with a sealed cover. The sealed container should be placed on a non-combustible
surface at a safe distance from combustible materials until the cinders have completely extinguished.
d
Do not though live cinders into organic waste containers.