E1 Connection Test; X.21 Connection Test; Site Reference Check - Motorola MTS LiTE Installation, Configuration And Basic Service Manual

For dimetra x core, dimetra express, dimetra ip scalable (dips), dimetra ip compact (dipc)/scalable.
Table of Contents

Advertisement

NOTICE: If all details for the status is needed, use the status bts –l command.
4 If any device drivers are reported as failed to initialize, perform further tests. To re-run
the tests, reset the Site Controller.
The failed to initialize status indicates a problem with that peripheral. A successful
initialization of a device does not guarantee that it is fully functional; further tests are required to
ensure this. The above tests are carried out upon power-up or reset. The command reports the
last status of the test.
For more details on available commands, see MTS Man Machine Interface Commands Manual
or use the help command.
NOTICE: This procedure may be halted and restarted at any time by pressing the
RESET push button for at least 2 seconds on the Site Controller front panel.
NOTICE: For Site controller indicators, see
6.4.2

E1 Connection Test

NOTICE: The E1 connection test requires that the Site Controller is connected to an active E1
line.
The E1 tests the connection between the Site Controller and the CNE core router. All applications that
communicate with the CNE utilize the Internet Protocol (IP).
To obtain the current state and statistics for IP, use the netstat and netstat -s commands.
The correct functioning of the IP layer may be determined through careful use of the ping command.
For more information, see the MTS MMI Commands Manual.
Enter the following loopback test command in Site Controller Test Application: e1el. MMI modes are
described in
MMI Commands and MTS Modes of Operation on page
6.4.3

X.21 Connection Test

NOTICE: The X.21 connection test requires the Site Controller to be connected to a Network
Terminating Unit (NTU) which supports the X.21 loop 3 command.
Enter the following loopback test command in Site Controller Test Application: e1el. MMI modes are
described in
MMI Commands and MTS Modes of Operation on page
6.4.4

Site Reference Check

The SRI status is checked from the Site Controller Application. MMI modes are described in
Commands and MTS Modes of Operation on page
Verify the GPS Receiver status as follows:
At the prompt, type: status sri
Verify that:
GPS State is GPS 3D FIX or GPS POSITION HOLD depending on the type of GPSR (internal/
external)
Chapter 6: Configuration and Testing
Site Controller on page
222.
222.
222.
6802800U74-AN
294.
MMI
233