6802800U74-AN
Chapter 7: Radio Frequency Distribution System
Insert the Cavity Combiner into the cabinet.
See
Inserting the Cavity Combiner into the Cabinet on page
2 For redundant ATCC only: Upgrade the redundant ATCC firmware.
See
Upgrading the Redundant ATCC Firmware on page
3 For ATCC only: Update the mapping list with the new unit TrackID.
See
Updating the Mapping List with the New TrackID on page
7.3.6.2.3
Inserting the Cavity Combiner into the Cabinet
Procedure:
1 Slide the Cavity Combiner into the cabinet.
2 Attach the TX and signal cables.
3 Fasten the three screws that hold the Cavity Combiner onto the brackets of the cabinet.
Two screws are on the left and one is on the right side of the Cavity Combiner.
4 Put the door of the cabinet back on.
5 Switch on the Power Supply Unit.
7.3.6.2.4
Upgrading the Redundant ATCC Firmware
Procedure:
1 Connect a PC with the TFTP server to the Base Station.
2 Place the new firmware on the TFTP server.
3 Log on to the Site Controller.
4 At the command prompt, enter:
tftp <IP address> get <tftp server directory>\SU11075-15.a90 /ffx/
SU11075-15.a90
The firmware is transferred from the PC to the Base station.
5 Load the file into the ATCC by entering atc 1 load_program /ffx/SU11075-15.a90 .
The firmware is loaded to the ATCC and the upload status displays.
6 Verify the successful upgrade by entering atc 1 get device_id.
The device ID matches the firmware version.
7.3.6.2.5
Updating the Mapping List with the New TrackID
Procedure:
1 Log on to the Site Controller.
2 View the mapping list by entering: can check_mapping.
Step example:
286
286.
286.
286.