The MTS supports the following alarm inputs and control outputs in all configurations:
15 opto-isolated 12 V alarm inputs
-
Alarm inputs and Alarm ground are floating
External alarms are connected to an External Alarm 2-16 port and one of the 6 GND (Alarm) ports
The 6 GND (Alarm) ports are connected internally
External alarm voltage (open) = 12 V typical
External alarm current (short circuit) = 8 mA typical
Control output 1 (2 pins) = alarm relay (Normally Open and Common contacts)
Control output 2 (2 pins) = alarm relay (Normally Open and Common contacts)
The alarms/outputs connections are located on the junction panel.
NOTICE:
Figure 82: MTS 2 Junction Panel Alarm Wiring Connection on page 138
83: MTS 4 Junction Panel Alarm Wiring Connection on page 139
the MTS Junction Panel. There may be small differences in older configurations.

Figure 81: MTS LiTE Junction Panel Alarm Wiring Connection