Standards Specifications; Table 116: Mts Standards Specifications - Motorola MTS LiTE Installation, Configuration And Basic Service Manual

For dimetra x core, dimetra express, dimetra ip scalable (dips), dimetra ip compact (dipc)/scalable.
Table of Contents

Advertisement

Environmental Speci-
fications
Humidity
Operational altitude
Environmental protec-
tion
Operating in use
Storage and Transpor-
tation
14.2.2

Standards Specifications

Table 116: MTS Standards Specifications

Standards Specifications
Harmonized EN for TETRA
Air-Interface
Conformance Test
EU Directives
Digital Line Interfaces: E1
Description
5% to 95% non-condensing for 30 C. EN 300 019 1-3 Class 3.2
-300 m to 3000 m
IP 20 according to IEC 60529
Shock: EN300 019-2-3 T 3.2
Vibration: EN300 019-2-3 T 3.2
Weather protected, not temperature-controlled storage locations.
ETSI EN 300 019-1-1 Class 1.2, and EN 300 019-2-1 T1.2
ETSI EN 300 019-1-2 Class2.3 public transportation, and EN 300
019-2-2 T2.3.
Description
EN 303 035-1: TErrestial Trunked RAdio TETRA
EN 302 561: TErrestial Trunked RAdio (TETRA)
EN 300 392-2
EN 300 394-1
R&TTE - Radio and Telecommunications Terminal Equipment
Directive 1999/5/EC
WEEE - Waste Electrical and Electronic Equipment Directive
2002/96/EC
RoHS - Restriction of Hazardous Substances Directive
2002/95/EC
ITU-T Rec. G. 703: Physical/electrical characteristics of hier-
archical digital interfaces.
Terminal Equipment Requirements (Site Controller and Rout-
ers):
TBR 12 (1993-12) / A1 (1996-01), which is a subset of EN
300 248 (Unstructured E1)
TBR 13 (1996-01) which is a subset of EN 300 420 (Struc-
tured E1)
Leased Line Requirements:
ETSI EN 300 418 v1.2.1 (2001-07) and ETSI EN 300 247
v1.2.1 (2001-07) (Unstructured E1)
ETSI EN 300 418 v1.2.1 (2001-07) and ETSI EN 300 419
v1.2.1 (2001-07) (Structured E1)