Chapter 13: MTS Troubleshooting
Indication
Possible Failure
Status LED:
BRC application is run-
GREEN, Alarm
ning but an alarm is pre-
LED: RED
venting the BR from key-
ing
SC1, SC2 LED:
Ethernet link not present
GREEN OFF
SC1, SC2 LED:
No ethernet activity
YELLOW OFF
396
Corrective Action
-
spr inet/if/eth0
-
spr inet/if/eth1
•
Check also if the IP suffix matches BR
Cabinet ID/Position ID combination, for
example: 10.0.253.cp where c = 1
(Cabinet ID) and p = 2 (Position ID)
give us 10.0.253.12. Use the following
command: cccp
•
Reset BR
•
Check logs through SC
•
Verify proper cabinet/position by exe-
cuting get cabinet, get position MMI
commands
•
Check BR IP addresses by executing
get ifconfig MMI command
•
Check for alarm conditions by execut-
ing get alarms MMI command or by
test application (PA temperature alarm,
lock and ref alarms, all receivers failed,
PA VSWR, alarm...)
•
Check the Power Amplifier by execut-
ing get pa_status MMI command
(check parameters: fwd power, fre-
quencies)
•
Start test application and check for cur-
rent alarms by executing test applica-
tion command: alarms -ofault_hndlr ;
check TX (transmitter) and RX (receiv-
er) frequency by executing freq -
otx_all, freq -orx_all test application
commands
•
Check reference signal from SC link
•
Reset BR
•
Replace BR
•
Check cabling to Site Controller
•
Check Site Controller status
•
If ethernet link present check proper IP
address by executing get ifconfig MMI
command
•
Check Site Controller IP address
•
Check connection to the Site Controller