Chapter 13: MTS Troubleshooting
Indication
Possible Failure
Status LED:
BRC application is run-
GREEN, Alarm
ning but an alarm is pre-
LED: RED
venting the BR from key-
ing
SC1, SC2 LED:
Ethernet link not present
GREEN OFF
SC1, SC2 LED:
No ethernet activity
YELLOW OFF
396
Corrective Action
-
spr inet/if/eth0
-
spr inet/if/eth1
Check also if the IP suffix matches BR
Cabinet ID/Position ID combination, for
example: 10.0.253.cp where c = 1
(Cabinet ID) and p = 2 (Position ID)
give us 10.0.253.12. Use the following
command: cccp
Reset BR
Check logs through SC
Verify proper cabinet/position by exe-
cuting get cabinet, get position MMI
commands
Check BR IP addresses by executing
get ifconfig MMI command
Check for alarm conditions by execut-
ing get alarms MMI command or by
test application (PA temperature alarm,
lock and ref alarms, all receivers failed,
PA VSWR, alarm...)
Check the Power Amplifier by execut-
ing get pa_status MMI command
(check parameters: fwd power, fre-
quencies)
Start test application and check for cur-
rent alarms by executing test applica-
tion command: alarms -ofault_hndlr ;
check TX (transmitter) and RX (receiv-
er) frequency by executing freq -
otx_all, freq -orx_all test application
commands
Check reference signal from SC link
Reset BR
Replace BR
Check cabling to Site Controller
Check Site Controller status
If ethernet link present check proper IP
address by executing get ifconfig MMI
command
Check Site Controller IP address
Check connection to the Site Controller