Can Bus Configuration; Psu Can Bus Commands - Motorola MTS LiTE Installation, Configuration And Basic Service Manual

For dimetra x core, dimetra express, dimetra ip scalable (dips), dimetra ip compact (dipc)/scalable.
Table of Contents

Advertisement

6802800U74-AN
Chapter 6: Configuration and Testing
Stop Bits: 1
2 Connect an RS232 cable from the serial port on the service terminal to the RJ45 Site Controller
service port on the front of the Site Controller.
6.3

CAN Bus Configuration

CAN Bus interconnects units in the BTS. It is used for signaling, configuration and troubleshooting.
CAN Bus configuration and diagnosis in done through use of MMI Commands from the Site
Controller. To use the commands connect the Service Terminal
229) to the Site Controller using the Service Cable
page
Description on page
227).
NOTICE: All the CAN Bus related Commands are covered in detail in the MMI Commands
manual.
Using CAN Bus MMI Commands it is possible to diagnose the state of all the devices connected to the
CAN Bus:
PSU CAN Bus Commands on page 230
Fans CAN Bus Commands on page 231
DPM CAN Bus Commands on page 231
ATCC CAN Bus Commands on page 231
Other CAN Bus Commands on page 232
6.3.1

PSU CAN Bus Commands

Use the PSU CAN Bus Commands to verify the state of the Power Supply Unit.
psu <PSU number> get alarm
Indicates a problem if any of the fail fields displays YES.
Example:
DC in fail: YES – indicates battery failure. For an MTS not equipped with backup battery it is
normal behavior and does not indicate any malfunction.
AC in fail: YES – indicates no or too low AC input voltage.
psu <PSU number> get status
Shows the status of all power sources (AC/DC, in/out).
psu <PSU number> get battery_voltage
Shows the battery voltage.
For an MTS not equipped with backup battery it shows the DC source input voltage.
psu <PSU number> get battery_current
Shows the battery current.
For an MTS not equipped with backup battery it shows the DC source input voltage.
psu <PSU number> get battery_temperature
Shows the battery temperature.
For an MTS not equipped with backup battery it shows the DC source input voltage.
230
(Setting Up Service Terminal on
(Service Cable and Connector Box

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents