Chapter 7: Radio Frequency Distribution System
Units are not present:
DPM 2 JTH0500105
Track ID not mapped:
JTH0500102
3 On the mapping list, locate the removed unit indicated as Units are not present.
4 Delete the old CAN Bus unit from the CAN Bus unit mapping list by entering: can
remove_mapping <X>.
<X> identifies the old unit name and is digit between 0 and 3.
Step example: can remove_mapping dpm 2.
5 Add the new CAN Bus unit to the CAN Bus unit mapping list by entering: add_mapping
dpm<X><track ID>.
<track ID> is a Track ID of the new unit.
<X> identifies the new unit name and is a digit between 0 and 3.
NOTICE: The new unit Track ID is present on the replaced unit label and indicated as
Track ID not mapped.
Step example: can add_mapping dpm 2 JTH0500102
6 View the updated mapping list by entering: can check_mapping.
7 On the mapping list, check that there are no units labeled as Track ID not mapped or
Units are not present.
7.2.4

Hybrid Combiner

The Hybrid Combiner is a part of the transmitter path in the RF Distribution System. The Hybrid
Combiner provides very reliable combining of up to two transmitters. The Hybrid Combiner has no
limitations in respect to channel spacing of the TX channels; however, for frequency planning and
interference reasons, at least 50 kHz is recommended.