Switching output
The switching output connection between SW IN/OUT (pin 5) and GND (pin 3) can be acti-
vated in the scanner setup.
In the basic setting, the SW IN/OUT switching output is switched to GND (pin 3) if a code is
recognized.
Figure 6.6:
ATTENTION!
Do not load the respective switching output of the BCL 8 with more than 20mA at
+5 ... 30VDC!
NOTE
You can configure the switching input/output according to your needs using the supplied
BCLConfig program.
Leuze electronic
4.75 ... 5.5 V DC
+ 5 ... 30 V DC
max. 20 mA !
GND
Switching output BCL 8
BCL 8
1
+ 5 V DC
Input resistance 36 k
R
5
L
SW_IN/OUT
3
GND
BCL 8