Technical data
Current consumption
Mechanical data
Degree of protection
Connection type
Weight
Dimensions (H x W x D)
Housing
Environmental data
Ambient temp. (operation/stor-
age)
Air humidity
Vibration
Shock
Electromagnetic compatibility
Conformity
Certifications
Table 4.1:
1)
For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
2)
These bar code readers shall be used with UL Listed Cable assemblies rated 30V,
0.5A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/
PVVA7)
4.2

LED indicators

Two, 3-color LEDs on the top of the housing indicate the device and read status:
LED
Status
LED
Decode
LED
Table 4.2:
14
Max. 250 mA (2 W power supply unit recommended)
IP 67
M12 connector, 5-pin, turnable or
Fixed cable, 2 m long, 5 x 0.25 mm
70g
Front beam exit: 48 x 40.3 x 15 mm
Lateral beam exit: 48 x 58 x 17.4 mm
Metal (diecast zinc)
0 °C ... +40 °C/-20 °C ... +60 °C
Max. 90% rel. humidity, non-condensing
IEC 60068-2-6, test Fc
IEC 60068-2-27, test Ea
EN 55022,
IEC 61000-4-2, -3, -4 and -6,
CE, FCC Class B, CDRH
UL 60950-1, C22.2 No. 60950-1
Technical data
Color
Green, flashing
Green, continuous
Red, flashing (200 ms)
Red, continuous
Orange, flashing (200 ms) Service operation
Green (200ms on)
Red (200ms off)
Orange, continuous
LED indicators
Meaning
Initialization phase
Operational readiness
Warning
Error, no function
Reading successful
No read result
Reading gate active
BCL 8
2
1) 2)
Leuze electronic