Host Interface Tab; Figure 10.5: Host Interface Tab - Leuze electronic BCL 8 Series Original Operating Instructions

Bar code reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

Deactivation
Switching input 1
function
Immediately after
the complete decod-
ing result is avail-
able
Command character The standard online character for the trigger end is the ´-´ character.
Time
Scans without info
10.4

Host interface tab

Figure 10.5: Host interface tab

Select the desired baud rate, the stop bits, the data bits, the parity and various transmission
modes here. These parameters are not active until following the automatic "Power-On" test
after the BCL 8 is switched on.
Leuze electronic
See menu "switching input"
If this item is activated, the read result is output immediately after the
bar code is decoded.
If the item is deactivated, the read result is sent only after the trigger
signal is returned (=end of reading gate).
This character can be changed only via the tree structure.
If the scanner is activated, the reading gate is automatically closed by
the scanner after this preset time has elapsed (e.g. for test purposes).
Following a successful read, the scanner waits for this number of
scans (sequential scans with no read result) before it automatically
deactivates itself.
BCL 8
Important parameters
51