Ma 8-01 - Sw In/Out - Switching Input And Switching Output; Figure 5.1: Ma 8-01 - Pin Assignment Sw In/Out - Leuze electronic BCL 8 Series Original Operating Instructions

Bar code reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

Accessories/order codes
5.3.2

MA 8-01 - SW IN/OUT - switching input and switching output

SWIN
4
5
FE
3
GND
SW IN/OUT
M12 socket
Figure 5.1:
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
NOTE
The switching input/switching output are programmed via the parameters in the BCLconfig
configuration software. For more information see also Chapter 10.6 and Chapter 10.8,
Page 54 et seq.
ATTENTION!
If you use a sensor with a standard M12 connector, then please note the following:
 Use only sensors on which the switching output does not lie on pin 2 or sensor cables
on which pin 2 is not assigned. Otherwise, the switching output is not protected against
feedback on the switching input. If the inverted sensor output lies on pin 2, erroneous
behavior of the switching output will result.
28
SW IN/OUT (5-pin socket, A-coded)
Pin
VOUT
1
1
2
2
3
SWOUT
4
5
Thread
MA 8-01 - Pin assignment SW IN/OUT
Name
Voltage supply for sensor system (VOUT
VOUT
identical to VIN at PWR IN)
SWOUT Switching output
GND
GND for the sensor system
SWIN
Switching input
FE
Functional earth
FE
Functional earth (housing)