Q12Dccpu-V - Mitsubishi Electric MELSEC Q Series User Manual

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

6.1.2

Q12DCCPU-V

(1) Initialization status
Initialization brings the Q12DCCPU-V into the following status:
(a) Default IP setting
• The execution of the script file registered on the "/ROM" drive (standard ROM) is stopped.
• The IP address of the Q12DCCPU-V is set to the default.
Built-in Ethernet port CH1
Built-in Ethernet port CH2
Script file
(b) Module initialization setting (Extended mode)
• Parameters are reset to the initial values.
• Battery backup RAM data is cleared to 0.
• "/ROM" drive (standard ROM) is formatted.
(All directories and files in the "/ROM" drive is deleted.)
Initialization deletes data in the Q12DCCPU-V.
Before you can perform the initialization, back up all necessary data, user programs and parameters.
(2) Operating procedure
(a) Preparation
Before initializing the Q12DCCPU-V, take the steps listed below:
1.
Install the module.
Install the power supply module and Q12DCCPU-V to the base unit.
Insert the C Controller module into the CPU slot.
Do not install any module other than a power supply module and the Q12DCCPU-V.
● For Q12DCCPU-V (Extended mode) with a serial number whose first five digits are "15102" or higher, the initialization
can be executed even if the module is mounted on the slot other than the CPU slot. When executing the initialization with
mounting Q12DCCPU-V (Extended mode) other than CPU slot, mount another CPU module on the CPU slot.
• Although an error may be detected on the CPU mounted on the CPU slot, the initialization can be executed.
2.
Check the wiring.
Check that the power supply wiring is property arranged.
Do not connect any cable other than power supply cables.
3.
Power on.
Check that the power supply voltage is within the specified range.
Check that the RUN/STOP/MODE switch is positioned in STOP.
Item
CHAPTER 6 HARDWARE OPERATIONS
Description
192.168.3.3
No setting
No file
6