Mitsubishi Electric MELSEC Q Series User Manual page 430

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Return value
(HEX)
-234
Event wait error
(FF16
)
• An error other than timeout occurred while waiting for the event.
H
-235
Number of event settings error
(FF15
)
• The specified number of event settings is out of range.
H
-236
Remote operation code error
(FF14
)
• The specified remote operation code is out of range.
H
Event source/event information character string error
• Any character other than one-byte alphanumeric ('a'-'z', 'A'-'Z', '0'-'9') is in event
-237
source "pcSrcStr[]".
(FF13
)
H
• Any character string 11 bytes or more is in event source "pcSrcStr[]".
• Any character string 201 bytes or more is in event information "pcAddMsg[]".
-238
Event log registration error
(FF12
)
• Event log registration has failed.
H
Memory card error
-239
• SD Memory card is not inserted.
(FF11
)
H
• CompactFlash card is not inserted.
-240
Clock data error
(FF10
)
• The clock data setting/clock data setting to be read is invalid.
H
Cycle error
-241
• The specified event cycle is out of range.
(FF0F
)
H
• The event cycle is being registered.
-242
Synchronization type error
(FF0E
)
• The specified synchronization type is out of range.
H
-243
SRAM size error
(FF0D
)
• The specified offset plus size is out of range.
H
Not executable during interrupt service routine
-245
• A value other than 1 (ISR) was specified in "sFlg", and the function was executed
(FF0B
)
H
as interrupt service routine.
-246
Timer event registration error
(FF0A
)
• Timer event registration has failed.
H
Program No. error
-247
• The specified program No. is out of range or invalid.
(FF09
)
SFC program No. (0 to 255)
H
Servo program No. (0 to 4095)
-248
Number of axes error
(FF08
)
• 9 or more axes was specified.
H
Axis type error
-249
• The specified axis type is not axis (stopped axis), synchronous encoder axis, or
(FF07
)
H
cam axis.
-250
Axis No. error
(FF06
)
• The specified axis No. is out of range.
H
-252
Torque limit value error
(FF04
)
• The specified torque limit value is out of range.
H
Device No. error
-253
• The specified device No. is out of range.
(FF03
)
H
• Device No. in the bit device settings is not a multiple of 16.
-254
Device type error
(FF02
)
• The specified device type is invalid.
H
-255
Size error
(FF01
)
• The specified start device No. plus size is out of range.
H
-256
Timeout error
(FF00
)
• A timeout occurred while waiting for response from other CPU.
H
-257
The value specified as the interrupt type is out of range.
(FEFF
)
H
-258
The value specified as the interrupt type is out of range.
(FEFE
)
H
No interrupt routine service registration
-259
• When an attempt was made to enable processing for an event (interrupt), the
(FEFD
)
H
processing was not registered.
428
Error description
Corrective action
• Ensure the operating system is not forcibly terminating the program.
• Check if the C Controller module is running normally.
• Reset the C Controller system.
Check the number of event settings.
Check the remote operation code.
Change the event source/event information character string.
Reset the C Controller system.
• Check if the SD memory card is inserted.
• Check if the CompactFlash card is inserted.
• Check the clock data setting.
• If this error occurred when reading the clock data, set the clock data.
• Check the specified event cycle.
• Check if the event cycle is being registered.
Check the specified synchronization type.
• Check the specified size.
• Check the offset plus size.
Specify 1 (ISR) in "sFlg" to correct the routine registered.
• Retry.
• Check if the C Controller module is running normally.
• Reset the C Controller system.
Correct the program No. in the user program.
Correct the number of axes in the user program.
Correct the axis type in the user program.
Correct the axis No. in the user program.
Correct the torque limit value in the user program.
Correct the start device No.
Correct the device type in the user program.
Correct the start device No. and size.
• Increase the timeout value in the user program.
• Correct the user program (including other tasks which execute Motion
CPU control/access functions)
• Check the program (user program, SFC program, or ladder program) of
the target CPU. (e.g., Add WAIT instruction to enable execution from
other CPU.)
Review the specified value, and specify a value that is within range.
Register the processing for the event (interrupt) and then execute the
operation once again.

Advertisement

Table of Contents
loading

Table of Contents