Auto Control Panel: Weld History - Kemppi X5 FastMig Series Operating Manual

Hide thumbs Also See for X5 FastMig Series:
Table of Contents

Advertisement

Available languages

Available languages

1.
Enter the actions menu by pressing the right control knob.
2.
Turn the control knob to highlight the desired action.
3.
Select the action by pressing the right control knob.
4.
Make further selections as required.
Available actions are:
Save changes: Save changes to the currently selected channel
Save to...: Save the current settings to another channel
Delete: Delete the currently selected channel
Create channel: Create a new channel based on the welding program(s)
>> MIG only: Welding programs can be filtered by base material, wire material, wire diameter, shielding gas and
process. For more information, refer to "Auto control panel: Applying welding programs" on page 79.
Create all: Create new channels based on all of the unused welding programs available (in MIG mode only)
Delete all: Delete all channels.
The skewed channel number in the top left corner of the channel selection indicates that the set welding parameters
are different from the ones currently saved on the active memory channel:
Tip: Changed welding parameters can be quickly saved onto the active memory channel by keeping the
Memory channels button pressed for approx. 2 seconds. This works in any view.

3.3.3 Auto control panel: Weld history

The Weld history view collects the information of the past welds (the last 10) into one view for later checking.