Summary of Contents for Kemppi FastMig MXF 63

  • Page 1 FastMig MXF 63, 65, 67 Operating manual Brugsanvisning Gebrauchsanweisung Manual de instrucciones Käyttöohje Manuel d’utilisation Manuale d’uso Gebruiksaanwijzing Bruksanvisning Instrukcja obsługi Manual de utilização Инструкции по эксплуатации Bruksanvisning 操作手册...
  • Page 3 OPERATING MANUAL English...
  • Page 4: Table Of Contents

    ................... . FastMig MXF 63, 65, 67...
  • Page 5: Preface

    This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specifications of the equipment can be found at the end of the manual. Please read the operating manual and the safety instructions booklet carefully before using the equipment for the first time.
  • Page 6: Installation

    Control panel Remote control connector Sub-feeder sync connector (kit optional) Gun water connections (cooling optional) Euro gun connector Shielding gas connection Connection for control cable Welding current cable connector Lead-in and clamping of cooling liquid hoses FastMig MXF 63, 65, 67...
  • Page 7: Connection Of System

    2.2.1 Liquid cooled system: FastMig power source + MXF + FastCool 10 MXF wire feed unit FastMig power source FastCool water cooler and power connection Gas supply MMA electrode holder Remote control device Liquid cooled welding Gun Power cable Earth return lead and clamp © Kemppi Oy / 1515...
  • Page 8: Assembly Of Mig/Mag System

    5. Mounting FastMig wire feed units to boom and swing arms When mounting wire feed units to boom and swing arms, the unit must be electrically isolated from both. Suspension angle of wire feed unit can be changed by moving the fixing point in handle. FastMig MXF 63, 65, 67...
  • Page 9: Accessories Corresponding To Wire Diameter

    Distance wire feeding is accommodated with WeldSnake and SuperSnake products in either air or liquid cooled models. Thermal and load protection is also designed to some Kemppi Gun models and feed units, so carefully consider your requirements and consult your local Kemppi sales team to ensure you choose the correct alternative for your needs.
  • Page 10: Loading The Filler Wire And Automatic Feed

    W007435 W007299 W007444 W007436 W007300 Fe, Mc, Fc 0.8 – 0.9 W007454 W007465 W007536 metal W007455 W007466 W007537 W007456 W007467 W007538 1.4 – 1.6 W007458 W007469 W007539 W007459 W007470 W007540 W007460 W007471 W007541 24.8.2005 12:55 FastMig MXF 63, 65, 67...
  • Page 11 W006086 W006087 Al, (Fc, Mc, Ss, Fe) W006088 W006089 U-groove W006090 W006091 W006092 W006093 Mount the lower feed roll, ensuring that the pin on the shaft fits in the cut on the feed roll. NOTE! © Kemppi Oy / 1515...
  • Page 12: Wire Liners

    Steel spiral liners carry the same colour coding as Kemppi machine feed rolls and drive rolls, making wire size, liner and drive roll matching easier if the gun is connected to Kemppi equipment. Steel spiral liners are suitable for welding solid and cored filler wires of corresponding wire diameter.
  • Page 13: Adjustment Of Pressure Arms

    Always use a good quality, 70 mm 2 heavy copper cable, and if possible a screw type 600 A clamp. Ensure that the surface contact to the work piece is clean of metal oxide and or paint. Make sure the clamp is firmly secured. © Kemppi Oy / 1515...
  • Page 14: Shielding Gas

    Remember to close gas bottle valve after welding. Parts of gas flow regulator Gas bottle valve Flow regulation screw Connecting nut Hose tail Hose tail nut Gas bottle pressure gauge Shielding gas flow meter FastMig MXF 63, 65, 67...
  • Page 15: Main Switch I/O

    Restart the power source and weld. SF 51/SF 54 weld ARC FORCE data DYNAMICS WIRE INCH GAS TEST m / min ARC FORCE DYNAMICS GAS TEST SETUP ARC FORCE DYNAMICS GAS TEST PANEL MR 200/MR 300 SF 51 © Kemppi Oy / 1515...
  • Page 16: Mxf Hanging Kit

    SF 53W and SF 54 or SF 51 and SF 52W panels enable compatibility with FastMig KMS power sources. MR 200, MR 300, MS 200 and MS 300 panels are compatible with FastMig M power sources. FastMig MXF 63, 65, 67...
  • Page 17: Control Panel Operations

    Finally secure the panel into place with the additional black plastic security clip provided (MXF 65 only). Ensure that the clip is positioned correctly. You will notice that the clip does not seat snuggly if its positioned upside down. MXF 63 + MXF 67 MXF 63 MXF 67 © Kemppi Oy / 1515...
  • Page 18: Welding Software Delivery Profile

    If you have a specific need beyond your standard equipment profile, check Kemppi DataStore for new welding software options or discuss with your supplier. FastMig Pulse is designed to allow customer specified welding software choice. Following delivery and installation your machine will include welding software specified at the point of order.
  • Page 19 Wire ø (mm) Shielding gas Process Number Ar+15–25%CO₂ 1-MIG Ar+15–25%CO₂ 1-MIG Ar+15–25%CO₂ 1-MIG Ar+15–25%CO₂ 1-MIG CO₂ 1-MIG CO₂ 1-MIG CO₂ 1-MIG CO₂ 1-MIG Fe Metal Ar+15–25%CO₂ 1-MIG Fe Metal CO₂ 1-MIG Fe Rutil Ar+15–25%CO₂ 1-MIG Fe Rutil CO₂ 1-MIG © Kemppi Oy / 1515...
  • Page 20 CrNiMo 19 12 Ar+2%CO₂ 1-MIG CrNiMo 19 12 Ar+2%CO₂ 1-MIG FC-CrNiMo 19 12 Ar+15–25%CO₂ 1-MIG More welding programs are available by purchasing MatchCurve and MatchCustom products. You can also order welding program packs together with WiseFusion function. FastMig MXF 63, 65, 67...
  • Page 21: Panel Button Functions

    13. Panel control/remote control unit selection, channel remote control (long press) *) Not included in standard delivery. See chapter Ordering numbers Automatic Weld Data display: Last recorded welding values are displayed post welding. See power source panel P65. Select MENU and then Weld Data. © Kemppi Oy / 1515...
  • Page 22: Pf 63 And Pf 65 Control Panel Button Functions

    Gas test will proceed after time adjustment is complete (short delay). Gas test can be stopped by pressing any button. (Gas test can also be started by pressing the Gas Test button inside the wire spool cabinet.) FastMig MXF 63, 65, 67...
  • Page 23: Wire Inch Button

    Short Press: 2T / 4T selection. Long Press: MatchLog ON/OFF selection if licence found. 5.2.8 Extra functions button Short Press: Crater Filling selection / Hot Start Selection. Long Press: MMA ON/OFF selection if licence found. © Kemppi Oy / 1515...
  • Page 24: Remote Selection Button

    Adjustments can be made before or during the arc process. This control also adjusts additional parameter values when selected. 5.2.11 Arc length/voltage/adjustment control knob Arc length, voltage and parameter adjustments can be made using this knob. Adjustments can be made before or during welding. FastMig MXF 63, 65, 67...
  • Page 25: Sf 51 And 54 Control Panel For Fastmig Kms

    Adjustment of MMA current c) Selection of SETUP parameter 12. a) Adjustment of welding voltage b) Adjustment of MIG dynamics or MMA Arc Force c) Adjustment of SETUP parameters 13. Manual control/remote control unit selection © Kemppi Oy / 1515...
  • Page 26: Sf 52W And 53W Control Panel For Fastmig Kms

    16. Manual control/remote control unit selection *) Minilog is not included in standard delivery **) Wise products are available as optional welding process solutions. Not included in the standard delivery. Please visit www.kemppi.com or Kemppi Datastore. FastMig MXF 63, 65, 67...
  • Page 27: Ms 200 And Ms 300 Control Panel For Fastmig M

    **) Wise products are available as optional welding process solutions. Not included in the standard delivery. Please visit www.kemppi.com or Kemppi Datastore. With MS 200 and MS 300 panels 'Wire Inch' and 'Gas Test' buttons should be used from inside NOTE! the wire feed unit.
  • Page 28: Mr 200 And Mr 300 Control Panel For Fastmig M

    Adjustment of MIG dynamics c) Adjustment of SETUP parameters 11. Manual control/remote control unit selection With MR 200 and MR 300 panels 'Wire Inch' and 'Gas Test' buttons should be used from NOTE! inside the wire feed unit. FastMig MXF 63, 65, 67...
  • Page 29: Basic Troubleshooting

    • Check power supply – 3 x phase present? Many of these checks may be carried out by the operator. However certain checks relating to NOTE! mains power must be completed by an authorised trained electrician. © Kemppi Oy / 1515...
  • Page 30: Maintenance

    The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
  • Page 31: Ordering Numbers

    FastMig MR 300 panel 6136200 FastMig MS 200 panel 6136300 FastMig MS 300 panel 6136400 FastMig M 320, 3 ~ 400V 6132320 FastMig M 420, 3 ~ 400V 6132420 FastMig M 520, 3 ~ 400V 6132520 © Kemppi Oy / 1515...
  • Page 32 MSF 55 & MXF 65 hanging kit W001694 KFH 1000 hanging device 6185100 KV 200 mounting kit for 2 wire feeders 6185249 Remote control units 6185419 R30 DataRemote 6185420 R30 DataRemote 10 m 618542001 RMT 10 (for PMT MIG gun) 6185475 FastMig MXF 63, 65, 67...
  • Page 33 6254206S12 WS 42 W Ss 1.0 mm 6254208S10 WS 42 W Ss 1.2 mm 6254208S12 For a complete list of welding guns, please visit Kemppi website at www.kemppi.com. Interconnection cable 1.8 m 6260401 Interconnection cable 6260405 Interconnection cable 10 m...
  • Page 34 Aluminium Pack 99904231 Steel Pack 99904232 Stainless Steel Pack 99904233 Work Pack + Wise Fusion 99904234 Aluminium Pack + Wise Fusion 99904235 Steel Pack + Wise Fusion 99904236 Stainless Steel Pack + Wise Fusion 99904237 FastMig MXF 63, 65, 67...
  • Page 35: Technical Data

    IP23S IP23S IP23S External dimensions L x W x H 510 x 200 x 310 mm 620 x 210 x 445 mm 625 x 243 x 476 mm Weight 9.4 kg 11.1 kg 12.5 kg © Kemppi Oy / 1515...