Kemppi X5 FastMig Series Operating Manual page 95

Hide thumbs Also See for X5 FastMig Series:
Table of Contents

Advertisement

Available languages

Available languages

40
VRD error
42
High current
in wire feeder
motor
43
Overcurrent in
wire feeder
motor
44
Wire speed
measurement
is missing
50
Welding pro-
gram error
62
Power source
not found
81
Welding pro-
gram data
missing
244
Internal
memory fail-
ure
250
Internal
memory fail-
ure
© Kemppi
Open circuit voltage exceeds the VRD limit.
There may be too much pressure in the wire
feed rolls or dirt in the wire line.
There may be too much pressure in the wire
feed rolls or dirt in the wire line.
Faulty sensor or wiring in wire feeder.
Required welding program is not installed.
No power source is connected to the wire
feeder, or connection is faulty.
Welding program data has been lost.
Initialization failed (%sub:%device).
Memory communication failed (%sub:%device).
Restart the power source. If problem persists, contact
Kemppi service.
Adjust the feed roll pressure. Clean the wire line. Change
worn parts in the welding gun.
Adjust the feed roll pressure. Clean the wire line. Change
worn parts in the welding gun.
Restart the welding system. If problem persists, contact
Kemppi service.
Contact Kemppi service for installing welding programs.
Check the control cable and its connectors.
Restart the power source. If problem persists, contact
Kemppi service.
Restart welding system. If problem persists, contact
Kemppi service.
Restart welding system. If problem persists, contact
Kemppi service.