Crater fill
- Crater fill time
- Crater fill wire feed speed
- Crater fill voltage
WF end step
Dynamics
Start arc length
Start arc time
Post current
Wire feed speed min
Wire feed speed max
Remote mode
Water cooler
Voltage display mode
Safe wire inch
Cable calibration
MMA settings
The parameters listed here are available for adjustment with the MMA process.
Parameter
© Kemppi
ON/OFF
Default = OFF
Min/Max = 0.1 ... 5 s, step 0.1 s
Default = 1.0 s
Min/Max = 0.5 ... 25 m/min
Step: 0.05 (if wire feed speed < 5 m/min),
0.1 (if wire feed speed >= 5 m/min)
Default: 5 m/min
Min/Max = 8 ... 60 V, step 0.1 V
Default = 18 V
ON/OFF
Default = OFF
Min/Max = -10.0 ... +10.0, step 0.2
Default = 0
-30 ... +30, step 1
Default = 0
-30 ... +30, step 1
Default = 0
-30 ... +30, step 1
Default = 0
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 0.5 m/min
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 25 m/min
OFF/Remote/Gun
Default = OFF
OFF/Auto/ON
Default = OFF
Terminal voltage / Arc voltage
Default = Arc voltage
ON/OFF
Default = OFF
Calibrate/Cancel
Parameter value
65
Operating manual - EN
When welding with high power, a crater is
usually formed at the end of the weld. The
Crater fill function decreases the welding
power / wire feed speed at the end of the
welding job so that the crater can be filled
using a lower power level. The Crater fill
level, voltage and time (only in 2T trigger
mode) are preset by the user.
Wire feed end step. This feature prevents
the filler wire from sticking to the work
piece when the welding ends. This is
accomplished by pulling the wire back
briefly.
Controls the short circuit behavior of the
arc. The lower the value the softer the arc,
the higher the value the rougher the arc.
Start arc settings affect the arc length and
duration at the ignition start.
Post current setting affects the wire length
at the weld end. This also enables the
optimum wire length for the start of the
next weld.
Minimum and maximum limits for the wire
feed speed adjustment.
If remote controller is not connected, this
selection is not available.
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm. When OFF, 5 m of filler
wire is fed.
The date and time and the calibration
information of the previous calibration is
also shown.
Refer to
"Calibrating welding cable" on
page 62
for cable calibration.