Purpose of Use
6020
Function for the extension module 1
6021
Function for the extension module 2
6022
Function for the extension module 3
6640
Clock mode (for the master or the slave boilers)
6630
Cascade master (to define the master boiler)
6600
Boiler LPB adresss
6601
Boiler segment number
7830 /
3-Way Mixing Valve or Plate heat exchanger
7832 /
temperature
7834
Dynamic pressure supervision shutdown in case of
2490
lockout
Static pressure supervision shutdown in case of
2480
lockout
(*) :
different sensor assignments as factory settings. The BX1 cascade sensor input for sensing the
hydraulic header temperature or BX2 the analog sensor input for the solar collector can be used
with the parameters 7820 and 7821.
4.5.
Easy Access to Parameters
The parameters embedded in the LMS 14 mainboard is classified for a quick access for authorized
services.
User menu and line number range
Day time and date
Opearator unit
Wireless
Time program heating circuit 1
Time program heating circuit 2
Time program 3 (Pump circuit)
Time program 4 (DHW)
Time program 5
Holiday program 1
Holiday program 2
Holiday program pump circuit
Heating circuit 1
Heating circuit 2
Rev: RINNAI Service manual (English)
Date:14/05/2019
unit
-
-
-
-
-
-
-
(
o
C)
RINNAI AUTHORIZATION
-
-
Parameter Range
1-6
20-70
120-140
500-516
520-536
540-556
560-576
600-616
641-648
651-658
661-668
710-900
1010-1200
100
Path / Information
(E: End user, F1: Comissioning, F2: Engineer, O:
OEM)
F2
Configuration
6020
F2
Configuration
6021
F2
Configuration
6022
F1
LPB system
6640
F2
LPB system
6630
F1
LPB system
6600
F2
LPB system
6601
It is possible to read the mixing circuit
temperature from the extension module. Read
the value from the BX21 sensor input of the
related extension module.
F1
Input/output test 7830/7832/7834
O Boiler 2490
O Boiler 2480