Now you completed the heating circuit with a mixing valve. You can now set the
heating circuit parameters and also time switch program.
NOTE: If you will use the heating circuit with mixing valve for the floor heating, you can adjust
the minimum and maximum temperature for the circuit. This circuit will acquire the
Go to the heating circuit page under the engineer level which has the floor heating and then
adjust the parameter 740 (minimum setpoint), 741 (maximum setpoint).
For the heating circuit 2, the parameters 1040 and 1041 will be adjusted.
For the heating circuit 2, the parameters 1340 and 1341 will be adjusted.
AGU 2.5 Extension Module and Its Relation With LMS 14
As in the below order the AGU expansion module can easily be mounted on the assigned place at
the back of the control panel. Place the two ratchets of the module to the holes vertically oriented
Rev: RINNAI Service manual (English)
Date:14/05/2019
76