Following the selection of the pump, you have to define the swimming pool temperature sensor. Also
assign the sensor to an appropriate sensor input terminal. Let it be BX2 (parameter 5911). Set its value to
Following the selection, set the value of a free H input terminal (like H6 or H7: parameters 6008/6011)
After all of these settings a menu line writen as
Engineer menu. In this menu you can set your desired pool temperature with the parameter below.
1959 | Flow temp setpoint
If the pool temperature sensor is sensing a temperature value lower than the set value, the pool pump will
start running for conveying heated water to the pool.
2056 | Setpoint source heating
The given examples in the upper text are prepared for creating a general knowledge and idea for
you in order to sample the possible types of errors and/or malfunctions and to their solutions.
For detailed service issues and problem solving demands, please get into contact with the
RINNAI After Sales Department.
Rev: RINNAI Service manual (English)
Date:14/05/2019
After then, bridge the H input terminal (short circuit).