3.

Product description

3.1

Intended use

i
Information on the intended use of the
BSA 43xx can be found in the product
descriptions for each of the components.
3.2

Measurement quantities

The BSA 43xx can be used to measure the following
quantities:
Brake dynamometer series BSA 43xx / BSA 44xx:
R
Braking force in kilonewtons [kN].
R
Braking force difference in percent [%].
R
Axle weight in kilograms [kg].
R
Deceleration in percent [%].
R
Out-of-roundness in percent [%].
Suspension tester SDL 43x:
R
Road surface adhesion in percent [%].
R
Resonant frequency in hertz [Hz].
Noise simulator SDL 435:
R
Resonant frequency in hertz [Hz].
Side slip tester SDL 410:
R
Toe measurement in millimeters [mm].
For further information on the measurement quantities,
refer to Section 10.2.
i
The SDL 43xx can be equipped with the BSA 43xx but not
with the BSA 44xx.
3.3
Measurement visualization
(operation)
3.3.1

General information

The measurement visualization function is started
together with the task manager and is designed to
assist the user as follows:
R
If in the order manager no order was generated
and activated, it is generated by the measurement
visualization automatically.
The order and the measurement results are stored
automatically in the order manager.
R
The user can select a tester and start the test
procedure.
R
The individual test steps are displayed in the
message line and presented on the screen in the
form of animated graphics.
Robert Bosch GmbH
Product description | BSA 43xx | 41
R
Measurement results are displayed on the screen in
numerical or graphical form.
R
Where necessary, the user is prompted to take
certain action during the test.
3.3.2

Check of calibration and configuration

The following data is displayed at startup (optional):
R
Firmware version
R
Last calibration date
R
Counter for configuration changes of the brake
tester
These data are important for customer service and rou-
tine testing.
3.3.3

Main window

The following illustration shows the main measurement
visualization window.
Fig. 1:
Main window
1 Remote control indicator
2 Message line
3 Mode indicator
4 Main menu
5 Tester selection zone
en
|