Introduction; System Overview - Pyronix ENFORCER Installation Manual

Hide thumbs Also See for ENFORCER:
Table of Contents

Advertisement

1 . I n t r o d u c t i o n
The Enforcer is a wireless alarm system that has been designed to enable easy installation and minimal
maintenance. The Enforcer protects the property (domestic or commercial) with a multitude of unique
features:
• Two Way Wireless Protection
• Signal Strength Indicator (SSI)
• Instant Two Way Device Control
• Pyronix High Security Wireless Protocol Encryption
• Programmable Wireless Supervision Time
• Intelligent Wireless Jamming Detection

1.1 System Overview

Areas:
Wireless Inputs (max):
Wired Inputs (max):
Total Inputs:
Outputs (max):
User / Manager Codes:
Duress / Guard Codes:
Code Combinations:
Communications:
Arming Devices (max):
Sirens:
Logs:
Remote Arm and Soak Test:
Event Signalling to UDL:
Memory Type:
Compliant to EN Grade
Environmental Class:
NOTE : All wireless learning is performed in the 'WIRELESS DEVICE CONTROL' menu, refer to the
programming manual for more details.
Compliance labelling should be removed or adjusted if non-compliant configurations are used.
Please note that technical functions for example fire, gas and flooding are not security graded as they are
outside the scope of EN50131-1 and EN50131-3.
Enforcer: Installation Manual
4 (4 Levels/Areas)
64 (32 x onboard, 1 x EURO-ZEM32-WE )
34 (2 x inputs on I/O board (Inputs 33-34) and 4 x ZEMs
(Inputs 35-66)
66
38 (1 x output module and 3 x outputs on I/O board, 4 on each ZEM
if EURO-ZEM8+ or EURO-ZEM8+PSU are used, 1 on each RKP)
80 (Max 32 x wireless keyfobs)
10
4294967295 (fully encrypted rolling code)
DIGI-GPRS, DIGI-LAN, DIGI-WI-FI, DIGI-GSM, DIGI-PSTN, DIGI-
PSTN/VOICE
4 wired keypads (EURO-LCDPZ) and/or 4 wireless keypads
(LEDRKP-WE). Internal or External Tag Readers.
2 Wireless Sirens or 2 Wired Sirens (in SCB mode)
750
EEPROM
*
:
2
II
Page: 3