5-4-2-4 Average Value (

This application calculates the average value of the measured values of the master unit and
slave units.
Slave unit 1
Master unit
• None of the connected slave units output the judgment result. (Always OFF)
• All sensor head indicators show the judgment result of the master unit.
• The response time for judgment output is the response time setting on the master unit and
slave units plus 3ms.

5-4-2-5 Standard Difference (

This application calculates the difference between the measured value of each slave unit and
the master unit.
With this application, each slave unit outputs the judgment result.
• The master unit performs judgment as a separate unit that does not perform calculation.
• The hold function cannot be used on the master unit.
• The response time for judgment output is the response time setting on the master unit and
slave units plus 3ms.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
SEN TRONIC
AG
Produkte, Support und Service
)
Slave unit 2
)
Slave unit 1
Master unit
(Measured value of "slave unit 2" - Measured value of "master unit")
is calculated value of master unit.
Rugghölzli 2
CH - 5453 Busslingen
([Master unit] + [Slave unit 1] + ... + [Slave unit n]) ÷ (1+n)
is calculated value of master unit.
"n" is the number of slave units
Slave unit 2
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
FUNCTION SETTINGS