*When the calculation function is used, the calculation value is "CALC".
<Reference>
● When self sample hold is selected, external trigger input is invalid.
● When a sensor head not connected error or pressure alarm / error is cleared, the same action
as a reset takes place.
Setting item
Self trigger level (SLF.LV)
●
You can set the level that starts stabilization diagnosis of the normal measured value (NORM.V).
* The self trigger level setting for self sample hold (static width) sets the level for start of sta-
bilization diagnosis of the internal judgment value.
Setting item
Self trigger level (SLF.LV)
Self trigger edge direction (SLF.EDG)
●
You can set the edge direction for triggering of the self trigger.
Setting item
Self trigger edge direction (SLF.EDG)
Self trigger delay (SLF.DLY)
●
You can set whether the normal measured value (NORM.V) is held after it stabilizes, or after
the delay time elapses.
Setting item
Self trigger delay (SLF.DLY)
Static width (DLY.WD)
●
You can set the static width (allowed fluctuation width) of the normal measured value (NORM.V).
Setting item
Static width (DLY.WD)
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
SEN TRONIC
AG
Produkte, Support und Service
Set values / setting range
-199.9999 to 199.9999 (mm)
Set values / setting range
Rise (UP)
Fall (DOWN)
Set values / setting range
Static width (DLY.WD)
Delay timer (DLY.TIM)
Set values / setting range
0 to 199.9999 (mm)
Rugghölzli 2
Tel. +41 (0)56 222 38 18
CH - 5453 Busslingen
Fax +41 (0)56 222 10 12
FUNCTION SETTINGS
Default value
0.5000
Default value
UP
Default value
DLY.WD
Default value
0.01
mailbox@sentronic.com
www.sentronic.com
5-39