Panasonic HG-S Series User Manual page 95

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

■ Peak Hold (Trigger mode: One-shot)
When the external trigger input is ON, the peak value during the sampling interval (external trig-
ger input OFF interval) is held as the judgment value (JUDGE.V).
When the external trigger input turns OFF, the next sampling interval starts.
Timing chart
HIGH set value
LOW set value
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. When the power is turned ON, the indeterminate state is held until the external trigger input
turns ON.
2. When the external trigger input turns ON (rising edge), the maximum normal measured value
(NORM.V) that occurs during the sampling interval is held as the judgment value (JUDGE.V).
3. If the reset input turns ON, the indeterminate state is held.
4. Judgment output outputs the judgment result based on the output setting.
*When the calculation function is used, the calculation value is "CALC".
<Reference>
The judgment value (JUDGE.V) is held in the same way in the respective measurement modes of
Bottom hold, Peak to peak hold, and Peak to peak hold / 2.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
SEN TRONIC
AG
Produkte, Support und Service
Indeterminate until TRIG
input turns ON when
power is turned ON
Normal measured value (NORM.V)*
Sampling interval
Sampling interval
Rugghölzli 2
CH - 5453 Busslingen
Maximum value (peak value) during
sampling interval
Sampling interval
Indeterminate after reset until TRIG input turns ON
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
FUNCTION SETTINGS
Judgment value
(JUDGE.V)
Sampling interval
mailbox@sentronic.com
www.sentronic.com
5-31

Advertisement

Table of Contents
loading

Table of Contents