5-1-3 Setting Items and Default Values

HIGH set value (HI.SET)
LOW set value (LO.SET)
Hysteresis (HYSTER)
Teaching type (TEACH)
Tolerance <±> (TOL<±>)
Preset value (PR. VAL)
Preset data selection
Basic
(PR.OBJ)
settings
(BASIC)
Preset save (PR.SAVE)
Measurement direction
(DIRECT)
Lever ratio (LEVER)
Response time (SPEED)
Output operation (OUTPUT)
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
SEN TRONIC
AG
Produkte, Support und Service
Setting item
Rugghölzli 2
CH - 5453 Busslingen
Setting range / set values
You can manually set any HIGH set value (upper limit value)
-199.9999 to 199.9999 (mm)
You can manually set any LOW set value (lower limit value)
-199.9999 to 199.9999 (mm)
If the judgment value (JUDGE.V) fluctuates near the HIGH
or LOW set value, the judgment output may repeat ON /
OFF and operation may become unstable. Operation can be
stabilized by increasing the hysteresis value.
0.0000 to 199.9999 (mm)
You can set the HIGH set value and LOW set value auto-
matically.
TCH.1 (1-point teaching) / TCH.2 (2-point teaching) / TCH.3
(3-point teaching)
When performing 1-point teaching, you can set a value equal
to the master workpiece judgment value (JUDGE.V) plus a
tolerance as the HIGH set value, and a value equal to the
master workpiece judgment value minus a tolerance as the
LOW set value.
When performing preset, you can shift (add or subtract) to
any preset value.
-199.9999 to 199.9999 (mm)
When using a preset, you can select the data (NORM.V or
JUDGE.V).
NORM.V (normal measured value) / JUDGE.V (judgment
value)
You can write preset information to EEPROM by setting pre-
set save to ON.
The preset ON / OFF state and offset values are saved even
when the power is turned OFF.
OFF (preset save OFF) / ON (preset save ON)
You can set whether the normal measured value (NORM.V)
and judgment value (JUDGE.V) are displayed normally (plus
direction) or in reverse (minus direction) when the sensor
head spindle is pressed in.
NORMAL (normal) / REVERS (reverse)
When using a lever for measurement, you can display the
measured value multiplied by the lever ratio as the judgment
value (JUDGE.V).
0.1 to 100.0
You can set the time until the judgment value (JUDGE.V) is
finalized (response time) when the sensor head starts mea-
surement.
3 (3ms) / 5 (5ms) / 10 (10ms) / 100 (100ms) 500 (500ms) /
1000 (1,000ms)
You can select the judgment output operation.
N.O. (normal open) / N.C. (normal closed)
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
FUNCTION SETTINGS
<Default value: 5.0000>
<Default value: 1.0000>
<Default value: 0.0030>
<Default value: TCH.1>
<Default value: 0.1000>
<Default value: 0.0000>
<Default value: NORM.V>
<Default value: OFF>
<Default value: NORMAL>
<Default value: 1.0>
<Default value: 100>
<Default value: N.O.>
mailbox@sentronic.com