Ng Hold - Panasonic HG-S Series User Manual

Contact-type digital displacement sensor
Hide thumbs Also See for HG-S Series:
Table of Contents

Advertisement

5-3-1-1-3 NG Hold

If a HIGH judgment or LOW judgment occurs during the interval specified by the external trigger
(TRIG input OFF interval), the judgment output is held. The judgment value (JUDGE.V) is not
held.
Timing chart
HIGH set value
LOW set value
ON
TRIG
indicator
OFF
ON
HOLD
indicator
OFF
Outputs OUT1 / OUT2 / OUT3 according to output setting.
1. The judgment output is held when the external trigger is OFF, but the judgment value
(JUDGE.V) is not held. The judgment output hold state is released by reset input. While the
external trigger is ON, the judgment value (JUDGE.V) and judgment output are held.
2. Reset input causes the judgment value (JUDGE. V) to become indeterminate until the aver-
age count is reached.
3. If the reset input turns ON while the external trigger is ON, the indeterminate state is held. If
a setting change causes the response time or judgment value (JUDGE. V) to change while
the external trigger is ON, reset occurs and the indeterminate state is held.
4. Judgment output outputs the judgment result according to the output setting.
<Reference>
● Once a HIGH judgment is output during one output judgment interval, a LOW judgment is not
output.
Once a LOW judgment is output, a HIGH judgment is not output.
● The trigger mode setting is invalid for NG hold.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
SEN TRONIC
AG
Produkte, Support und Service
Normal measured
value (NORM.V)*
Hold
interval
Output judgment interval
Rugghölzli 2
CH - 5453 Busslingen
Judgment value (JUDGE.V)
Hold
interval
Output judgment interval
NG hold
NG
hold
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
FUNCTION SETTINGS
Output judg-
ment interval
Hold interval
mailbox@sentronic.com
www.sentronic.com
Output judg-
ment interval
5-33

Advertisement

Table of Contents
loading

Table of Contents