GE VersaMax IC200PWR001 User Manual page 84

Table of Contents

Advertisement

3
Specifications
Input Voltage
Input Power
Holdup Time
Inrush Current
Output Voltage
Protection
Output Current
Wiring
DC- must be grounded to frame / earth ground. DC- is grounded to frame
internally in the Power Supply. As a result, floating power supplies cannot be
used.
For agency compliance, external MOV suppression as detailed in chapter 2 is
required from both the positive and negative inputs to frame ground or at the
power line input of a system enclosure. MOV protection across the inputs is
provided on the supply and not necessary to add externally.
3-16
VersaMax Modules, Power Supplies and CarriersUser's Manual
9.6 to 15 V DC, 12V DC nominal
11W
10ms
25 A at 12V DC
30A at 15 V DC
5 V DC, 3.3 V DC
Short circuit, overload, reverse polarity
Total
1.5 A maximum
3.3 V DC Output
0.25 A maximum
5 V DC Output
(1.5 A - I
The total output current should not exceed 1.5 A. For example, if
3.3 V at 0.25 A is required, 1.25 A is available on the 5 V output.
DC+
12V DC Power Supply
) maximum
3.3 V
DC-
IC200PWR201
GFK-1504N