ANL
C, <src-bit>
Function:
Logical AND for bit variables
Description:
If the Boolean value of the source bit is a logic 0 then clear the carry flag; otherwise
leave the carry flag in its current state. A slash ("/" preceding the operand in the
assembly language indicates that the logical complement of the addressed bit is
used as the source value, but the source bit itself is not affected . No other flags are
affected.
Only direct bit addressing is allowed for the source operand.
Example:
Set the carry flag if, and only if, P1.0 = 1, ACC.7 = 1, and OV = 0:
MOV
ANL
ANL
ANL
C,bit
Operation:
ANL
(C) ← (C) ∧ (bit)
Encoding:
1 0 0 0
Bytes:
2
Cycles:
2
ANL
C,/bit
Operation:
ANL
(C) ← (C) ∧ ¬ (bit)
Encoding:
1 0 1 1
Bytes:
2
Cycles:
2
Semiconductor Group
C,P1.0
C,ACC.7
C,/OV
0 0 1 0
0 0 0 0
; Load carry with input pin state
; AND carry with accumulator bit 7
; AND with inverse of overflow flag
bit address
*
bit address
145
Instruction Set

Advertisement

loading

This manual is also suitable for:

Sab 80c515Sab 80c535Sab 80535Sab 80515k