Remote Analog Programming Procedure - Xantrex XPR 10-600 Operating Manual

Xpr 6000 watt series programmable dc power supply
Table of Contents

Advertisement

Remote Operation
Select Remote Control Function
Resistive programming is selected at rear panel switch S1: S1-1 and S1-2 are ON.
Remote
Analog
Programming
Procedure
1. Turn the power supply OFF.
2. Set switches S1-1, S1-2, S1-3, and S1-4 according to the programming sources
3. Connect the programming source(s) to the mating J1 connector as indicated in
4. Set the programming sources to the desired levels and turn the power supply ON.
62
CAUTION
!
Before turning on the power supply in resistive programming mode, make sure
that the resistors are connected at J1-1 to J1-3 and J1-2 to J1-3.
CAUTION
!
To maintain the isolation of the power supply output and prevent ground loops,
use an isolated (ungrounded) programming source when operating the power
supply via remote analog control at the J1 connector.
CAUTION
!
The remote programming inputs are internally referenced to the supply's
negative output. Do not connect control ground (J1 terminals 3 or 6) to the
supply's positive output.
that you are using, as indicated in
23. See
Table 4.3, on page 63
Figure 1.5, on page 22
Ensure that the mating connector is plugged securely into the rear panel
connector.
The LCL LED turns off and the RMT LED turns on. Adjust the external
programming source to change the power supply's output.
Figure 1.5, on page 22
for more information about switch settings.
and connect the correct polarity for voltage sources.
Operating Manual for XPR Series Power Supply
and
Table 1.2, on page