Front Panel Function Checks - Xantrex XPR 10-600 Operating Manual

Xpr 6000 watt series programmable dc power supply
Table of Contents

Advertisement

Installation
Basic Tests
Front Panel
1. Turn the front panel power switch to ON.
Function
2. Set voltage and current controls fully clockwise. Push the OUT ON/OFF switch
Checks
3. Press the OUT ON/OFF switch to its IN position.
4. Press the OVP CHECK switch and check that the voltmeter displays
5. Turn the OVP SET potentiometer counter-clockwise and check that the
6. Press the OUT ON/OFF switch to its OUT position.
7. Press the SET POINT switch and check that the voltmeter and ammeter display
8. Turn the front panel power switch to OFF.
38
to its IN position and check that the voltmeter reading falls to zero and the OFF
(OUTPUT OFF) LED turns on. Push the OUT ON/OFF switch once again to
reset it to its OUT position. The OFF LED turns off and the voltmeter reading
returns to its previous value.
approximately the model-rated output voltage plus 10%.
voltmeter reading decreases. Continued turning (up to 20 turns) will see the
reading decrease to approximately 5% of the model-rated voltage output. Turn
the OVP SET potentiometer clockwise until the voltmeter once again displays
approximately the model-rated output voltage plus 10%.
approximately the power supply output ratings.
Operating Manual for XPR Series Power Supply

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents