Output Performance Specifications

These specifications define the electrical performance specifications of the power
supply output. These specifications apply to both local and remote sense
configurations, except where noted. These specifications apply to all programming
sources, except where noted.
Rated Output Range
Voltage
Current
Efficiency
Load Regulation
Voltage
Current
Line Regulation
Voltage
Current
Programming Range for Voltage and Current
Voltage and Current
OVP Programming Range
Typical Programming Resolution
Front Panel or Control Resolution
Front Panel Voltage and Current Meters
3.5-digit green numeric LED displays. For accuracy
see
Release 1.1
0–100%
0–100%
Typical 89% efficiency at nominal line voltage and ambient temperature.
Minimum 82% efficiency. Specific minimum efficiency limits are model
dependent.
5 mV + 0.05% of Vmax
20 mA + 0.1% of Imax
0.01% of Vmax
0.05% of Imax
From 0–103% of the rated maximum output
0–103% of maximum rated voltage
Voltage
Current
Table A.1, on page 66
0.02% of Vmax
0.02% of Imax
and
Table A.3, on page
Specifications and Characteristics