Alarms

The possible alarms are:
These conditions have corresponding indicator LEDs on the front panel (see
Figure 1.1, on page 18
Release 1.1
WARNING- Fire Hazard
If an over-voltage, over-current, or over-power protection error persists without
apparent cause, press OUT ON/OFF button to disable the output, and turn the AC
switch OFF. Inspect the load and power supply for evidence of an electrical fault. The
power supply should not be brought back into operation if there is any evidence of an
electrical fire or other safety hazards.
AC - AC Input is out of range, non-latching shutdown
OTP - Internal over temperature condition, latching or non-latching, S1 selects
INT - External interlock is active (see Interlock
OVP - Output over voltage condition, latching shutdown
SNS - Output remote sense line fault, latching shutdown
and
Figure 1.2, on page
19.)
page
53)
Operation
Alarms
57