Xpr 6000 watt series programmable dc power supply
Table of Contents

Advertisement

Table A.4Drift Specifications for 6000 Watt units (80V to 600V Models)
Models
1
Drift (30 minutes):
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
2
Drift (8 hours):
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
Temperature Coefficient:
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
3. Change in output per °C change in ambient temperature, with constant line and load.
Release 1.1
80–75
32 mV
450 mA
16 mV
30 mA
3
32 mV
45 mA
Specifications and Characteristics
Electrical Specifications—Summary
100–60
150–40
40 mV
60 mV
360 mA
240 mA
20 mV
30 mV
24 mA
16 mA
40 mV
60 mV
36 mA
24 mA
300–20
600–10
120 mV
240 mV
120 mA
60 mA
60 mV
120 mV
8 mA
4 mA
120 mV
240 mV
12 mA
6 mA