Remote Analog Programming Procedure - Xantrex XHR 7.5-130 Operating Manual

Xhr 1000 watt series programmable dc power supply
Table of Contents

Advertisement

Remote Operation
Remote Analog Programming of Output Voltage and Current Limit
Remote
Analog
Programming
Procedure
1. Turn the power supply OFF.
2. Using
3. Install any J2 connector jumpers as indicated in
4. Connect the programming source(s) to the rear panel J2 connector as shown in
5. Set the programming sources to the desired levels and turn the power supply ON.
6. Adjust the external programming source to change the power supply's output.
Notes:
68
CAUTION
!
To maintain the isolation of the power supply output and prevent ground loops,
use an isolated (ungrounded) programming source when operating the power
supply via remote analog control at the J2 connector.
CAUTION
!
The remote programming inputs are internally referenced to the supply's
negative output. Do not connect control ground (rear panel J2 connector terminal
J2-3 or J2-6) to the supply's positive output.
Table
4.1, set switches SW1-1, SW1-2, SW1-3, and SW1-4 according to
the selected programming sources. See Notes at the end of this procedure for
more information about switch settings.
Figure
4.1, observing the correct polarity for voltage sources.
The REM LED turns on.
Switches SW-1 to SW-4 can be set to their defaults (all open) unless otherwise
specified in
Table
Switches SW1-5, SW1-6, SW1-7, and SW1-8 are not required for remote
programming. They can remain at the settings you have selected for your
application.
Resetting switches SW1-3 or SW1-4, the programming scale selection switches,
may require that you recalibrate the programming circuit to maintain
programming accuracy. See
The control circuits have been designed to allow you to set output voltage and
current up to 5% over the model-rated maximum values. The power supply will
operate within these extended ranges, but we cannot guarantee full performance
to specification.
4.1. See
SW1 Programming Switch
Calibrating for Programming
Table
4.1.
for default settings.
Accuracy.
Operating Manual for XHR Series Power Supply

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents