Specifications and Characteristics
Electrical Specifications—Summary
Table A.3Specifications for 6000 Watt units (80V to 600V Models)
Models
Output Ratings:
1
Output Voltage
2
Output Current
Output Power
3
Line Regulation:
Voltage (0.01% of Vmax)
Current (0.05% of Imax)
4
Load Regulation:
Voltage (0.05% of Vmax + 5 mV)
Current (0.1% of Imax + 20 mA)
Meter Accuracy:
Voltage (0.5% of Vmax + 1 count)
Current (0.5% of Imax + 1 count)
Output Noise (0–20 MHz):
Voltage (p–p)
Output Ripple (rms):
Voltage
5
Current
OVP Adjustment Range:
(0% to 103% of Vmax)
6
Efficiency:
1. Minimum output voltage is <0.3% of rated voltage at zero output setting.
2. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
3. For input voltage variation over the AC input voltage range, with constant rated load.
4. For 0–100% load variation, with constant nominal line voltage.
5. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
6. Typical efficiency at nominal input voltage and full output power.
68
80–75
100–60
0–80 V
0–100 V
0–75 A
0–60 A
6000 W
6000 W
8 mV
10 mV
37.5 mA
30 mA
45 mV
55 mV
95 mA
80 mA
0.5 V
0.6 V
0.48 A
0.4 A
100 mV
100 mV
15 mV
20 mV
320 mA
230 mA
0–88 V
0–110 V
0.89
0.90
Operating Manual for XPR Series Power Supply
150–40
300–20
0–150 V
0–300 V
0–40 A
0–20 A
6000 W
6000 W
15 mV
30 mV
20 mA
10 mA
80 mV
155 mV
60 mA
40 mA
1.75 V
2.5 V
0.3 A
0.2 A
150 mV
250 mV
20 mV
30 mV
120 mA
50 mA
0–165 V
0–330 V
0.90
0.91
600–10
0–600 V
0–10 A
6000 W
60 mV
5 mA
305 mV
30 mA
4.0 V
0.06 A
350 mV
80 mV
25 mA
0–660 V
0.91