Installation
Load Connections
Single Load To connect a single load to the DC output bus bars (5–80V outputs):
1. Ensure that the power supply is powered OFF.
2. Place a 5/16 in. (M8) bolt in the connecting hole of the negative bus bar, and
3. Using a wrench, turn the bolt until it is secure at approximately 25 foot-pounds
4. Fasten the positive wire or bus bar to the positive bus, using a bolt, flatwasher,
5. Tighten the bolt to approximately 25 foot-pounds (34Nm).
6. Ensure that the positive and negative wires are arranged so bare wires do not
To connect the DC output wire clamp connectors (100–600V outputs):
42
fasten the negative wire or bus bar, a flatwasher, lockwasher, and a nut to the
bolt.
(34Nm).
lockwasher, and nut.
come into contact with each other or the chassis.
Connect appropriately sized wires as described in steps 1 to 6 above, except strip
0.5 in. (13 mm) of insulation off each load wire, and clamp in the output
connector by securely tightening the vertical clamp screw for each output.