CONNECT TANK TO FILL STATION

1. Connect tanks one and two to the left side plumbing tee with 1" hose. Secure with the supplied hose clamps.
2. Connect the tee outlet to the pump one fill station common port with 1" hose. Secure with the supplied hose
clamps.
3. Connect tank three to the pump two fill station common port with 1" hose. Secure with the supplied hose
clamps.

CONNECT FILL STATION TO PUMP

1. Connect the fill station for pump one to pump one plumbing with 1" hose. Secure with the supplied hose
clamps.
2. Connect the fill station for pump two to pump two plumbing with 1" hose. Secure with the supplied hose
clamps.

CONNECT RINSE

1. Connect the 3/4" hose to the rinse port of the rinse 3-way valve located under the tank. Secure with the
supplied hose clamps.
2. Route the hose to the rear of the machine.
3. Determine an appropriate location in front of the skid lower cross tube to install the rinse tee.
4. Cut the hose and install the rinse tee. Secure with the supplied hose clamps.
5. Connect the rinse tee to pumps one and two. Secure with the supplied hose clamps.

CONNECT PUMP RECIRCULATION OUTLET TO TANK

1. Connect the pump one recirculation output to tank one port with 1/2" hose. Secure with the supplied hose
clamps.
2. Connect the pump two recirculation output to the tank three port with 1/2" hose. Secure with the supplied hose
clamps.

CONNECT PUMP TO INJECTION POINT

1. Connect the pump one output to the injection point on the mixer with 1/2" hose. Secure with the supplied hose
clamps.
2. Connect the pump two output to the injection point on the mixer with 1/2" hose. Secure with the supplied hose
clamps.

CONNECT OVERFLOW

1. Connect a 1" hose to the overflow ports on the tops of the tanks. Secure with the supplied hose clamps.
2. Route the hose down the side of the cages. Secure the hose to the cages using the supplied zip ties.

FOUR TANKS WITH TWO PUMPS PLUMBING INSTALLATION

NOTE:
Refer to Figure 7 on page 52 for a plumbing schematic for four tanks with two pumps.