Alarms - Raven ICD Sidekick Pro Installation Manual

Injection for case trident
Table of Contents

Advertisement

C
4
HAPTER
TABLE 1. LED Status Indicators
LED
Logic Power
High Current Power
CAN Status
Flow Switch State
Calibration Switch State

ALARMS

TABLE 2. Diagnostic Trouble Codes
Code ID
523152
31
Invalid pump state
9
Lost communication
16
Target flow too high
523154
18
Target flow too low
1
Chemical tank is empty
523160
17
Low tank volume remaining
Injection pressure sensor
2
disconnected
523167
16
High injection pressure
38
If logic power is present at the motor control node, the logic power indicator will
be on.
If high current power is present at the motor control node, the high current power
indicator will be on.
The CAN status indicator will flash once per second if the motor ECU is
communication on the CANbus. If the motor control ECU cannot communicate via
the CANbus, the CAN status indicator will flash four times per second.
The flow switch indicator will flash when flow is detected from both sides of the
pump.
The calibration switch indicator will flash when a metal object is passed by the
calibration switch sensor.
Description
ICD Sidekick Pro Injection for Case Trident Installation Manual
Status Display
Recommended Actions
Verify the communication setup/shutdown
alarm.
Verify the communication setup/shutdown
alarm.
1. Reduce the equipment speed.
2. Reduce the target application rate.
1. Increase the equipment speed.
2. Increase the target application rate.
Refill the product to continue field
applications.
Refill the product to continue field
applications.
1. Verify good connection to the pressure
sensor on the pump.
2. Verify the sensor is getting supply voltage.
3. Verify the signal voltage is getting back to
the pump ECU.
1. Verify the communication setup/shutdown
alarm.
2. Check for an obstruction in the injection
system discharge hose.
3. Verify the carrier pressure is not exceeding
150 PSI.