Accumulated Status, Status, And Fault Registers - Xantrex RS232-HPD Operating Manual

Xantrex technology internal rs-232 interface for xt/hpd series programmable dc power supplies operating manual: models rs232-xt, rs232-hpd
Table of Contents

Advertisement

Accumulated Status, Status, and Fault Registers

Release 1.1
The RS-232 option card uses three separate registers which are always active. They
are the accumulated status, status, and fault registers. You can use the status
commands shown in Table 3.6, "Status Commands" to activate the registers. The
bit register has eight conditions, each assigned a bit weight. When querying a
register, the controller returns a response which is the sum of the weights of all
relevant conditions.
Example:
ASTS?
ASTS 771
771 = 512 + 256 + 2 + 1 = PON + REM + CC + CV
The accumulated status register shows that PON, REM, CC and CV have all been
active since the last accumulated status register query.
Table 3.8 shows the mnemonics and bit weights which correspond to each register
condition. You can select conditions you want to monitor in the fault and status
register by using the MASK and UNMASK commands.
Accumulated Status, Status, and Fault Registers
Query the Accumulated Status register.
Controller response.
Operation
49

Advertisement