Mounting; Installation Site; Installation On A Carrier Rail; Removal From Carrier Rail - WAGO 852-1322 Manual

Managed switch; 8 port gb; macsec/ 6 port gb; 2foc; macsec
Hide thumbs Also See for 852-1322:
Table of Contents

Advertisement

852-1322/852-1328 Industrial Managed Switch
Pos: 22. 1 /Alle Se rien (
4

Mounting

Pos: 22. 2 /Seri e 85 2 (E THERNET- Zub ehö r)/ Monti ere n/M onta geo rt 8 52- x30x @ 24 \mo d_1 452 256 5413 88_ 21. docx @ 19 7891 @ 2 @ 1
4.1

Installation Site

The location selected to install the industrial managed switch may greatly affect
its performance. When selecting a site, we recommend considering the following
rules:
Install the industrial managed switch at an appropriate place. See Section
"Device Description" > ... > "Technical Data" > ... > "Environmental
Conditions" for the acceptable temperature and humidity operating ranges.
Make sure that the heat output from the industrial managed switch and ventilation
around it is adequate. Do not place any heavy objects on the industrial managed
switch.
4.2

Installation on a Carrier Rail

The carrier rail must optimally support the EMC measures integrated into the
system and the shielding of the internal data bus connections.
Place the industrial managed switch onto the DIN rail from the top and snap it
into position.
4.3

Removal from Carrier Rail

To remove the industrial managed switch from the carrier rail, insert a suitable
tool into the metal tab under the switch and deflect the metal tab downward.
You can then release the switch down from the carrier rail and remove it
upwards.