Device Description
3.3

Display Elements

Pos: 20. 14 /Se rie 8 52 (ETHERNET- Zu beh ör) /Ger äte besch reib ung/A nzeige ele ment e/LED-Anz eige n 85 2-1 505 , -1 505 /000 -00 1 @ 31\ mod _15 2472 262 281 4_2 1.do cx @ 4 837 18 @ 33 @ 1
The industrial managed switch is equipped with device LEDs and port LEDs. You
can see the status quickly with the device LEDs, while the port LEDs provide
information about connection actions.
3.3.1

Unit-LEDs

Figure 6: Device-LEDs

Table 7: Legend for "Device LEDs" Figure

LED
PWR
RPS
ALM
3.3.2

Port-LEDs

Figure 7: Port-LEDs

Table 8: Legend for "Port LEDs" Figure

LED
LINK/ACT
100M/1G
Pos: 20. 15 /D okum ent ation allge mein/ Gliede run gsele me nte/ ---Sei tenwe chsel --- @ 3\ mod _12 211 080 450 78_ 0.docx @ 2 181 0 @ @ 1
Manual
1.0.01
Name
Primary-Power-
LED
Redundant-Power-
System-LED
Alarm-LED
Name
1000BASE T- Ports LED
(1 LED for each port)
10/100/1000BASE T-
Ports LED
(1 LED for each port)
852-1322/852-1328 Industrial Managed Switch
Status
Description
Green
The industrial managed switch uses the primary
power supply.
Off
The primary power supply has been switched
off, or a fault has occurred.
Green
The industrial managed switch uses the
redundant power supply.
Off
The redundant power supply has been switched
off, or a fault has occurred.
Red
Either PWR or RPS power input is missing
Status
Description
Green
Port in operation.
Flashes
Data traffic being routed via the port.
Off
No proper link established at the port.
Amber
Port in operation at 100/1000 Mbit/s.
Off
Port in operation at 10 Mbit/s or not linked.