852-1322/852-1328 Industrial Managed Switch
Pos: 20. 9 /Seri e 85 2 (E THERNET- Zub ehö r)/G erä teb eschr eibu ng/Ansc hlüsse /Anschlüs se 8 52- 150 5_0 00- 001 Sp ann ungs vers org ung @ 33 \mo d_1 542 286 086 447 _21. docx @ 50 833 2 @ 3 @ 1
3.2.2
Power Supply (PWR/RPS)
The female connector (Item No. 2231-105/026-000) can easily be connected to
the 5-pole male connector (Item No. 231-435/001-000) located on the top of the
switch.
Both PWR and RPS support input voltage between 9 and 48 VDC.
The male connector shows the following pin assignment:
Figure 4: Power Supply Connector
Table 5: Legend for Figure "Power Supply (PWR/RPS/F.G.)"
Connection
+
-
+
-
Warning: Damage to property caused by electrostatic discharge (ESD)!
DC Powered Switch: Power is supplied through an external DC power source.
Since the switch does not include a power switch, plugging its power adapter into
a power outlet will immediately power it on.
Description
Description
RPS
Secondary DC input
RPS
Secondary DC input
PWR
Primary DC input
PWR
Primary DC input
F.G.
Functional Ground
Device Description