Table 37: Modbus-Register - WAGO 852-1322 Manual

Managed switch; 8 port gb; macsec/ 6 port gb; 2foc; macsec
Hide thumbs Also See for 852-1322:
Table of Contents

Advertisement

80
Appendix

Table 37: Modbus-Register

Address
Port Status
0x1000
(4096)
0x1040
(4160)
0x10A0
(4256)
31.8
Manual
1.0.01
Data Type
Read/Write
5 words
R
5 words
R
5 words
R
852-1322/852-1328 Industrial Managed Switch
Description
Port Status
0x0000: Disabled
0x0001: Enabled
Word 0 Hi byte = Port 1 Status
Word 0 Lo byte = Port 2 Status
Word 1 Hi byte = Port 3 Status
Word 1 Lo byte = Port 4 Status
Word 2 Hi byte = Port 5 Status
Word 2 Lo byte = Port 6 Status
Word 3 Hi byte = Port 7 Status
Word 3 Lo byte = Port 8 Status
Word 4 Hi byte = Port 9 Status
Word 4 Lo byte = Port 10 Status
Port Speed
Status, 10M = 0x01
Status, 100M = 0x02
Status, 1000M = 0x03
Word 0 Hi byte = Port 1 Status
Word 0 Lo byte = Port 2 Status
Word 1 Hi byte = Port 3 Status
Word 1 Lo byte = Port 4 Status
Word 2 Hi byte = Port 5 Status
Word 2 Lo byte = Port 6 Status
Word 3 Hi byte = Port 7 Status
Word 3 Lo byte = Port 8 Status
Word 4 Hi byte = Port 9 Status
Word 4 Lo byte = Port 10 Status
Port Link Status
Status, down = 0x00
Status, up = 0x01
Word 0 Hi byte = Port 1 Status
Word 0 Lo byte = Port 2 Status
Word 1 Hi byte = Port 3 Status
Word 1 Lo byte = Port 4 Status
Word 2 Hi byte = Port 5 Status
Word 2 Lo byte = Port 6 Status
Word 3 Hi byte = Port 7 Status
Word 3 Lo byte = Port 8 Status
Word 4 Hi byte = Port 9 Status
Word 4 Lo byte = Port 10 Status

Advertisement

Table of Contents
loading

This manual is also suitable for:

852-1328

Table of Contents