Table 28: Wbm "Diagnostics" Page - "Modbus Tcp" Tab - WAGO 852-1322 Manual

Managed switch; 8 port gb; macsec/ 6 port gb; 2foc; macsec
Hide thumbs Also See for 852-1322:
Table of Contents

Advertisement

60
Configuration in the WBM
To set a Modbus Address for the industrial managed switch, choose a number
from 1 to 247 and enter it in the Modbus Address field. Click [Submit] button to
configure it. To enable the Modbus protocol on the industrial managed switch,
check the box behind the Modbus Enable and set a Modbus Port number by
choosing a number from 1 to 65535 and enter that number in the Modbus Port
field. Click [Submit] button to set the Modbus TCP. Table "WBM "Diagnostics"
Page – "Modbus TCP" Tab" summarizes the descriptions of the Modbus TCP's
parameters.
Please refer to Appendix 0 for the Modbus Memory mapping.
Table 28: WBM "Diagnostics" Page – "Modbus TCP" Tab
Parameters
Modbus
Address
Modbus Enable Uncheck
Modbus Port
Manual
1.0.01
852-1322/852-1328 Industrial Managed Switch
Factory Default
Description
1
Enter a number from 1 to 247 to set the Modbus Address of
the industrial managed switch.
Enable the Modbus protocol on the industrial managed switch
by checking the Modbus Enable box.
502
Enter a number from 1 to 65535 to set the Modbus service port
number for the industrial managed switch.