28

Connect Devices

Pos: 24 /Alle Serie n (Allge mein e M odul e)/Üb ersc hrift en/Ebe ne 1/Ge räte ansc hließ en - Übe rsch rift 1 @ 3\ mo d_12 341 728 894 68_ 21.d ocx @ 274 60 @ 1 @ 1
5
Connect Devices
5.1

Power Supply

The switch uses direct current power supply of 9 ... 48 V.
The primary and secondary power supply pins are connected via a 5-pin plug-in
connection located on the top of the industrial managed switch.
The female connector (Item No. 2231-105/026-000) is composed of five
connecting terminals and can be inserted and removed easily by hand to connect
to the 5-pin plug connector located on the top of the switch.
The power supply for the switch automatically adjusts to the local power source
and can also be switched on if no or not all patch cables are connected.
1. Connect a suitable grounding conductor to the grounding lug on the top of the
switch.
Ground for the switch
The ground for the switch prevents electromagnetic interference from
electromagnetic radiation.
Observe the corresponding standards for EMC-compatible installations as well.
2. Plug the female connector into the male connector of the switch if it has not
already been plugged in. Check the tight fit of the multipoint connector by
gently shaking it.
3. PWR +/-:
To connect or disconnect the conductors, actuate the spring directly in the
female connector using a screwdriver or an operating tool and insert or
remove the conductor.
4. Check whether the power LED "PWR" on the top of the device lights up when
power is supplied to the device. If not, check to ensure that the power cable is
plugged in correctly and fits securely.
5. RPS +/-:
To connect or disconnect the conductors, actuate the spring in the female
connector directly using a screwdriver or an operating tool and insert or
remove the conductor.
6. Check whether the power LED "RPS" on the top of the device lights up when
power is supplied to the device. If not, check to ensure that the power cable is
plugged in correctly and fits securely.