Before attempting any work around the PCS100, observe the following precautions:
Remove any watches, rings, or other metallic accessories.
Only use tools with insulated handles.
Wear rubber gloves and boots.
Do not lay tools or metal parts on top of the cabinet.
Removing an AC Softstart Contactor
1. Open the front door. See "Opening a Front Door" on page 20.
2. Remove the safety cover. See "Removing a Safety Cover" on page 34.
3. Locate the AC softstart contactor.
4. Remove the screws securing the AC softstart contactor and the wires.
5. Remove the AC softstart contactor and the wires.
Maintenance Manual
ON
OFF
Figure 148. AC Softstart Contactor Location
Figure 149. Disconnecting the Wires
107
KM 2
ON
OFF
Maintenance