ATTENTION: Capacitors on the DC bus can retain hazardous voltages after input power has been removed. Before working on the iTRAK power supply, wait the
full-time interval as indicated in the warning on the power supply. Failure to observe this precaution could result in severe bodily injury or loss of life.
Use the following wiring diagrams to connect your iTRAK power supply.
Connect an iTRAK Power Supply to a System
DC-bus Power Supply
DC+
SH
DC+
Bonded Cabinet
(1)
DC-
Ground Bus
Optional
2198-TCON-24VDCIN36
Chassis
24V Input Power
Wiring Connector
1
Customer Supplied
+24V
+24V DC
2
24V_COM
(1)
Power Supply
1
IN1
2
COM
3
IN2
4
SHLD
EN–
Connect
CONT EN–
contactor enable
EN+
CONT EN+
(1)
circuitry
(1) Customer supplied.
(2) Make only one of these 24V COM connections.
2198-Pxxx
2198T-W25K-ER
Kinetix 5700
Kinetix 5700 iTRAK Power
Supply
Cable Shield
Clamp
Shunt Power
(RC) Connector
DC Power Bus A
(IDC) Connector
DC Bus Bar
100 mm link
DC+
DC Bus
(DC) Connectors
DC-
DC Power Bus B
(IDC) Connector
+24V
Control Power
24V_COM
(CP) Connectors
Optional
2198T-W25K-P-T
T-connectors and Bus Bars
(IOD) Connector
Digital Input
(IOD) Connector
Contactor Enable
(CED) Connector
iTRAK Power Supply
Ready (IR) Connector
Three-phase Input
(IPD) Connector
PE Ground
L3 L2 L1
Connect to
three-phase
power input
Rockwell Automation Publication 2198T-IN001C-EN-P - October 2019
Kinetix 5700 iTRAK Power Supply and iTRAK Bus Conditioner Module