Kinetix 5700 iTRAK Power Supply and iTRAK Bus Conditioner Module
Ground the Power Supply to the Subpanel
Ground Kinetix 5700 iTRAK power supply to a bonded-cabinet ground bus with a braided ground strap. Keep the braided ground strap as short as
possible for optimum bonding.
Connect the Braided Ground Strap
Item
Description
1
Ground screw (green) 2.0 N•m (17.5 lb•in), max
2
Braided ground strap (customer supplied)
3
Ground grid or power distribution ground
4
Bonded-cabinet ground bus (customer supplied)
12
iTRAK Power Supply
(typical example)
1
2
3
Braided Ground Straps
4
12 mm (0.5 in.) by 0.8 mm (0.03 in.)
Keep straps as short as possible.
Rockwell Automation Publication 2198T-IN001C-EN-P - October 2019
Kinetix 5700 Servo Drives
(typical system)